A HEPA filter is one that captures at least what share of particles 0.3 microns in size?

  1. 90 percent
  2. 95 percent
  3. 99 percent
  4. 99.97 percent
Show the answer

D. 99.97 percent

A HEPA filter removes at least 99.97 percent of particles 0.3 microns in diameter. Filters rated 95 or 99 percent sound close but pass many times more fine dust.

Reference: 40 CFR 745.83 (HEPA vacuum)

Before the protective sheeting is taken up, what must be done with paint chips and debris?

  1. Sweep them into a corner for later
  2. Collect them and seal them in a heavy-duty bag
  3. Blow them outside the house with compressed air
  4. Leave them for the final vacuuming
Show the answer

B. Collect them and seal them in a heavy-duty bag

The first cleaning step is to collect all paint chips and debris and seal them in a heavy-duty bag without spreading them. Compressed air and dry sweeping scatter lead dust.

Reference: 40 CFR 745.85(a)(5)

How are walls in the work area cleaned after an interior renovation?

  1. Dusted with a dry brush, from the floor up
  2. Rinsed with a garden hose
  3. HEPA vacuumed or wiped with a damp cloth, from the ceiling down
  4. Left alone unless paint was removed from them
Show the answer

C. HEPA vacuumed or wiped with a damp cloth, from the ceiling down

Walls are cleaned starting at the ceiling and working down to the floor, by HEPA vacuuming or wiping with a damp cloth. Dry brushing just moves the dust into the air.

Reference: 40 CFR 745.85(a)(5)(ii)(A)