경간 6 m인 단순보에 등분포하중 10 kN/m(보 자중 포함)가 작용한다. 한쪽 지점의 수직 반력은 몇 kN인가?
Answer in kN.
Show the answer
30 kN
전체 하중 = 10 × 6 = 60 kN. 대칭이므로 한쪽 반력 = 60 / 2 = 30 kN.
Reference: 구조역학 기본 원리(정역학, 재료역학)
건축시공, 건축구조, 건축계획, 건설안전 기술, 산업안전보건 법령에 관한 한국어 연습 문제입니다. 공개된 법령과 기준에 따라 작성합니다.
10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.
Unlock timed mock exams
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor and the seller of record, adds tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@tradeexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the mock exam to use it.
경간 6 m인 단순보에 등분포하중 10 kN/m(보 자중 포함)가 작용한다. 한쪽 지점의 수직 반력은 몇 kN인가?
Answer in kN.
30 kN
전체 하중 = 10 × 6 = 60 kN. 대칭이므로 한쪽 반력 = 60 / 2 = 30 kN.
Reference: 구조역학 기본 원리(정역학, 재료역학)
실내 공기의 수증기량(절대습도)이 일정할 때 실온을 높이면 상대습도는 어떻게 됩니까?
B. 낮아진다
온도가 오르면 공기가 담을 수 있는 포화 수증기량이 커지므로 같은 수증기량이면 포화도(상대습도)는 낮아집니다. 높아진다고 생각하는 것은 절대습도와 혼동한 오류입니다.
Reference: 건축설비 교재: 건축환경 및 열 환경 기초
철근콘크리트 보에서 수직 이음(이어치기)을 둘 때 가장 알맞은 위치는?
C. 전단력이 작은 스팬 중앙부 부근
이음부는 약점이 되므로 전단력이 작은 곳에 둡니다. 보와 슬래브는 스팬 중앙 부근이 해당합니다. 기둥 접합부 쪽은 전단력이 커서 부적합합니다.
Reference: 건축시공학: 철근콘크리트공사(이어치기 위치)
타워크레인 운전 작업을 중지해야 하는 순간풍속의 기준으로 맞는 것은?
A. 초당 15m 초과
운전 작업은 순간풍속이 초당 15m를 넘으면 중지한다. 초당 10m 초과는 설치·수리·점검·해체 작업의 중지 기준이므로 운전 기준과 혼동하지 않는다.
Reference: 산업안전보건기준에 관한 규칙(2026-11 현재 시행본) 제153조, 제142조
콘크리트 슬럼프 시험으로 알 수 있는 것은 무엇입니까?
B. 반죽 질기(유동성의 정도)
슬럼프 값은 굳지 않은 콘크리트가 얼마나 묽은지 보여 줍니다. 강도는 공시체를 만들어 압축시험으로 따로 확인합니다.
Reference: KS F 2402 콘크리트의 슬럼프 시험 방법