Sample questions
Under the Florida Building Code, 8th Edition (2023), which construction types are built with noncombustible materials throughout the structure?
Types I and III
Types I and II
Types II and V
Types III and IV
Show the answer
B. Types I and II
Types I and II use noncombustible materials for the structure. Type III allows combustible interior elements, Type IV is heavy timber, and Type V may be entirely combustible.
Reference: FBC, Building, 8th Edition (2023), Sections 602.2 and 602.3
Under the Florida Building Code, 8th Edition (2023), exit signs must stay lit if building power fails. For how long must their emergency power supply last?
30 minutes
60 minutes
90 minutes
120 minutes
Show the answer
C. 90 minutes
Exit signs and egress lighting need emergency power for 90 minutes. Thirty or 60 minutes would leave people in the dark during a long evacuation of a large building.
Reference: FBC, Building, 8th Edition (2023), Sections 1008.3 and 1013
Under the Florida Building Code, 8th Edition (2023), what is the minimum illumination at the walking surface of the means of egress while the building is occupied?
0.1 foot-candle
5 foot-candles
10 foot-candles
1 foot-candle
Show the answer
D. 1 foot-candle
The egress path must be lit to at least 1 foot-candle at floor level. A tenth of that is the figure people often confuse it with from emergency-power rules, and the higher values apply to task lighting, not egress.