Why should fiberglass batt insulation not be stuffed into a cavity that is too small for it?

  1. It makes the wall weaker
  2. Compressing it lowers its insulating value
  3. It increases the vapor passing through the wall
  4. It makes the batt burn faster
Show the answer

B. Compressing it lowers its insulating value

Batts insulate by trapping still air. When they are crushed the air space shrinks and the R-value drops below the label. Compression has no structural effect.

Reference: General building construction practice (edition-independent)

Wood studs conduct heat faster than the insulation between them. What is this called?

  1. Convection looping
  2. Vapor drive
  3. Thermal bridging
  4. Radiant shading
Show the answer

C. Thermal bridging

Heat flows through the framing around the insulation, which is thermal bridging. Continuous insulation outside the framing reduces it. Vapor drive is moisture movement, not heat flow.

Reference: General building construction practice (edition-independent)

When hanging drywall on a wall, why are the end joints of adjacent rows staggered?

  1. To save on the number of screws
  2. To make taping unnecessary
  3. To let the framing breathe
  4. To avoid long continuous seams that tend to crack
Show the answer

D. To avoid long continuous seams that tend to crack

Staggered joints keep seams from lining up in one long weak line that cracks with movement. They do not reduce screws or remove the need to tape.

Reference: General building construction practice (edition-independent)