TradeExamPro

Swimming Pool Contractor Practice Test

Practice questions on swimming pool and spa construction: excavation and shell, plumbing and hydraulics, electrical bonding, water chemistry, and safety and barrier rules.

175 questions · 5 topics · start free, no sign-up

Start practising

Mixed practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

Under NEC 2023, what is the maximum length of the flexible cord on a cord-and-plug connected pool pump?

  1. 3 feet
  2. 6 feet
  3. 10 feet
  4. 25 feet
Show the answer

A. 3 feet

Cord-and-plug connection of stationary pool equipment is allowed for easy removal for maintenance, but the cord is limited to 3 ft (0.9 m) and needs a copper grounding conductor and a grounding-type plug. A longer cord would be allowed for portable tools but not for pool equipment.

Reference: NEC 2023, 680.7(A)

A pump keeps losing prime and the strainer basket shows a steady stream of tiny bubbles. Water level and basket are fine. Where is the most likely problem?

  1. Suction-side air leak
  2. A dirty filter on the discharge side
  3. A closed return valve
  4. An oversized impeller
Show the answer

A. Suction-side air leak

Bubbles on the suction side mean air is being drawn in, commonly through a dry or worn lid O-ring or loose fitting. A dirty filter or closed return makes pressure rise but does not pull air into the pump.

Reference: Pump troubleshooting (manufacturer manual)

The ISPSC 2024 model code uses a test sphere on barrier openings. What size sphere must not pass through any opening?

  1. 6-inch sphere
  2. 8-inch sphere
  3. 10-inch sphere
  4. 4-inch sphere
Show the answer

D. 4-inch sphere

A 4-inch sphere must not pass through a barrier opening, which stops a small child from slipping through. A 6-inch or larger opening would be big enough for a toddler to pass.

Reference: ICC International Swimming Pool and Spa Code 2024, Section 305 (barriers)

Workers must step into a 6-foot-deep pool excavation cut in loose, sandy soil. What does OSHA require?

  1. Nothing, because pool digs are exempt from the rule
  2. A protective system such as sloping, shoring or a shield
  3. Only a warning barricade around the top
  4. Only a ladder at one end
Show the answer

B. A protective system such as sloping, shoring or a shield

Excavations 5 feet or deeper need a protective system unless they are cut in stable rock, and loose sand is far from that. A barricade and a ladder are needed too but do not stop a cave-in.

Reference: 29 CFR 1926.652(a)(1) (protective systems for excavations 5 feet or deeper)

A pool has low pH, low alkalinity and low calcium hardness. What is the likely effect on the plaster and metal fittings?

  1. The water is scaling and will coat the tile with deposits
  2. The water is balanced and needs no change
  3. The water mostly causes cloudy water but no damage
  4. The water is corrosive and can etch plaster and attack metal
Show the answer

D. The water is corrosive and can etch plaster and attack metal

With all three low the saturation index is negative, so the water pulls minerals out of plaster and corrodes metal. Scaling comes from the opposite condition.

Reference: PHTA Certified Pool & Spa Operator Handbook, water chemistry chapters

Exams this helps with

ExamWho runs itWhere
Swimming pool contractorState boardsUnited States (varies by state)