TradeExamPro

Pool plumbing hydraulics practice questions

35 questions from the Swimming pool contractor practice test.

Start practising

Pool plumbing hydraulics practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Sample questions

A pump keeps losing prime and the strainer basket shows a steady stream of tiny bubbles. Water level and basket are fine. Where is the most likely problem?

  1. Suction-side air leak
  2. A dirty filter on the discharge side
  3. A closed return valve
  4. An oversized impeller
Show the answer

A. Suction-side air leak

Bubbles on the suction side mean air is being drawn in, commonly through a dry or worn lid O-ring or loose fitting. A dirty filter or closed return makes pressure rise but does not pull air into the pump.

Reference: Pump troubleshooting (manufacturer manual)

A filter reads 12 psi clean. It now reads 22 psi, and the manufacturer says to clean when pressure is 8 to 10 psi above the clean reading. What should be done?

  1. Open the return valves further
  2. Add more sand to the filter
  3. Raise the pump speed
  4. Backwash or clean the filter
Show the answer

D. Backwash or clean the filter

A rise of 10 psi means the media is loaded, so it needs cleaning. Raising speed would only push pressure higher and cut flow more.

Reference: Filter operation and cleaning (manufacturer manual)

How is a pleated cartridge filter normally cleaned?

  1. Backwash it through a multiport valve
  2. Remove cartridge and hose it off
  3. Pour DE powder over the pleats
  4. Run the pump in recirculate
Show the answer

B. Remove cartridge and hose it off

Cartridge filters have no backwash cycle; the element is taken out and washed by hand. DE and multiport backwash apply to other filter types.

Reference: Cartridge filter maintenance (manufacturer manual)

Other topics