Which item is found on the data plate of a manufactured home?
The roof load zone and wind load zone for which the home was designed
The name of the retailer who sold it
The foundation type chosen by the installer
The local permit number
Show the answer
A. The roof load zone and wind load zone for which the home was designed
The data plate records design information such as the roof load and wind zones, the plant, serial number and model. Sales, permit and foundation details are created after the home leaves the factory so they cannot be on it.
Reference: 24 CFR 3280.5
A hole was cut in the roof of a multi-section home during set-up. Before exterior close-up is finished, what must be done with it?
Seal it with a roofing-suitable sealant or material
Leave it open for a day so trapped moisture can escape
Cover it with plastic sheeting and tape the edges
Pack it with fiberglass insulation and cover it with felt
Show the answer
A. Seal it with a roofing-suitable sealant or material
Roof holes must be made weatherproof before close-up is complete, using material suited to the roof covering. Plastic or insulation alone does not stay watertight on a roof.
Reference: 24 CFR 3285.801(d), eCFR current as of Nov 2026
How far from each end of the home may the first pier under a main I-beam be placed, at most?
12 inches
24 inches
36 inches
48 inches
Show the answer
B. 24 inches
Piers supporting the frame must be within 24 inches of each end. Placing them farther in leaves the end of the frame overhanging too far.
Reference: 24 CFR 3285.310(c) (eCFR, in force November 2026)
A site must be graded at the minimum slope away from the foundation. How many inches lower must the ground be 10 feet from the foundation than it is at the foundation?
Answer in inches.
Show the answer
5 inches
Minimum slope is 1/2 inch per foot. Over 10 feet: 10 x 0.5 = 5 inches.
Reference: 24 CFR 3285.203 (eCFR, current November 2026)
What is the minimum slope for drain lines under a manufactured home unless the schematic says otherwise?
1/8 inch per foot
1/4 inch per foot
1/2 inch per foot
1 inch per 10 feet
Show the answer
B. 1/4 inch per foot
The general minimum grade is 1/4 inch per foot toward the outlet. 1/8 inch per foot is only allowed with a clean-out at the upper end of the run.
Reference: 24 CFR 3285.604 (eCFR, current Nov 2026)