Practice questions on installing manufactured homes: HUD regulations, site preparation, foundations and piers, anchoring, utility connections and finishing, based on public federal regulations.

164 questions · 5 topics · start free, no sign-up

Start practising

Mixed practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

Which item is found on the data plate of a manufactured home?

  1. The roof load zone and wind load zone for which the home was designed
  2. The name of the retailer who sold it
  3. The foundation type chosen by the installer
  4. The local permit number
Show the answer

A. The roof load zone and wind load zone for which the home was designed

The data plate records design information such as the roof load and wind zones, the plant, serial number and model. Sales, permit and foundation details are created after the home leaves the factory so they cannot be on it.

Reference: 24 CFR 3280.5

A hole was cut in the roof of a multi-section home during set-up. Before exterior close-up is finished, what must be done with it?

  1. Seal it with a roofing-suitable sealant or material
  2. Leave it open for a day so trapped moisture can escape
  3. Cover it with plastic sheeting and tape the edges
  4. Pack it with fiberglass insulation and cover it with felt
Show the answer

A. Seal it with a roofing-suitable sealant or material

Roof holes must be made weatherproof before close-up is complete, using material suited to the roof covering. Plastic or insulation alone does not stay watertight on a roof.

Reference: 24 CFR 3285.801(d), eCFR current as of Nov 2026

How far from each end of the home may the first pier under a main I-beam be placed, at most?

  1. 12 inches
  2. 24 inches
  3. 36 inches
  4. 48 inches
Show the answer

B. 24 inches

Piers supporting the frame must be within 24 inches of each end. Placing them farther in leaves the end of the frame overhanging too far.

Reference: 24 CFR 3285.310(c) (eCFR, in force November 2026)

A site must be graded at the minimum slope away from the foundation. How many inches lower must the ground be 10 feet from the foundation than it is at the foundation?

Answer in inches.

Show the answer

5 inches

Minimum slope is 1/2 inch per foot. Over 10 feet: 10 x 0.5 = 5 inches.

Reference: 24 CFR 3285.203 (eCFR, current November 2026)

What is the minimum slope for drain lines under a manufactured home unless the schematic says otherwise?

  1. 1/8 inch per foot
  2. 1/4 inch per foot
  3. 1/2 inch per foot
  4. 1 inch per 10 feet
Show the answer

B. 1/4 inch per foot

The general minimum grade is 1/4 inch per foot toward the outlet. 1/8 inch per foot is only allowed with a clean-out at the upper end of the run.

Reference: 24 CFR 3285.604 (eCFR, current Nov 2026)