TradeExamPro

Mh piers anchoring practice questions

35 questions from the Manufactured home installer practice test.

Start practising

Mh piers anchoring practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Sample questions

How far from each end of the home may the first pier under a main I-beam be placed, at most?

  1. 12 inches
  2. 24 inches
  3. 36 inches
  4. 48 inches
Show the answer

B. 24 inches

Piers supporting the frame must be within 24 inches of each end. Placing them farther in leaves the end of the frame overhanging too far.

Reference: 24 CFR 3285.310(c) (eCFR, in force November 2026)

What is the maximum spacing, on center, of piers under the main rails when using the general rule for frame supports?

  1. 96 inches
  2. 144 inches
  3. 120 inches
  4. 180 inches
Show the answer

C. 120 inches

Piers under main rails may be no more than 120 inches (10 feet) on center. Closer spacing may be needed for the load and soil.

Reference: 24 CFR 3285.310(c) (eCFR, in force November 2026)

A hollow concrete block pier is capped with a solid concrete cap. What is the minimum nominal thickness of that cap?

  1. 1 inch
  2. 2 inches
  3. 3 inches
  4. 4 inches
Show the answer

D. 4 inches

A solid concrete or masonry cap must be at least 4 inches thick nominal. Two inches is the figure for hardwood lumber caps.

Reference: 24 CFR 3285.304(b) (eCFR, in force November 2026)

Other topics