10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
A site must be graded at the minimum slope away from the foundation. How many inches lower must the ground be 10 feet from the foundation than it is at the foundation?
Answer in inches.
Show the answer
5 inches
Minimum slope is 1/2 inch per foot. Over 10 feet: 10 x 0.5 = 5 inches.
Reference: 24 CFR 3285.203 (eCFR, current November 2026)
Fill under footings must be compacted to at least what percent of maximum relative density?
85 percent
90 percent
95 percent
100 percent
Show the answer
B. 90 percent
Foundation supports must sit on undisturbed soil or on fill compacted to at least 90 percent of maximum relative density. Anything looser can settle under the pier load.
Reference: 24 CFR 3285.201 and 3285.312 (eCFR, current November 2026)
How much must the seams of a ground vapor retarder overlap?
2 inches
6 inches
12 inches
24 inches
Show the answer
C. 12 inches
Joints in the sheeting overlap at least 12 inches so moisture cannot pass through the seams. A 6-inch lap is too short to meet the rule.
Reference: 24 CFR 3285.204 (eCFR, current November 2026)