What is the minimum slope for drain lines under a manufactured home unless the schematic says otherwise?

  1. 1/8 inch per foot
  2. 1/4 inch per foot
  3. 1/2 inch per foot
  4. 1 inch per 10 feet
Show the answer

B. 1/4 inch per foot

The general minimum grade is 1/4 inch per foot toward the outlet. 1/8 inch per foot is only allowed with a clean-out at the upper end of the run.

Reference: 24 CFR 3285.604 (eCFR, current Nov 2026)

A drain run cannot be graded at 1/4 inch per foot. What allows a 1/8 inch per foot slope?

  1. An extra vent installed at the lower end of the run
  2. Doubling the pipe diameter
  3. A clean-out at the upper end of the run
  4. Using flexible corrugated pipe in the whole run
Show the answer

C. A clean-out at the upper end of the run

The standard permits 1/8 inch per foot when a clean-out is installed at the upper end of the run, so the line can be cleared. Pipe size, venting or pipe type do not change the grade requirement.

Reference: 24 CFR 3285.604 (eCFR, current Nov 2026)

A water system will be tested with air only after site completion. What must be done first?

  1. Close the shutoff to the water heater only
  2. Fill the water heater with hot water
  3. Remove the pressure-reducing valve
  4. Disconnect the water heater
Show the answer

D. Disconnect the water heater

The standard says to disconnect the water heater before an air-only test, so air pressure is not applied to the tank. Test requirements otherwise follow the piping manufacturer's instructions.

Reference: 24 CFR 3285.603 (eCFR, current Nov 2026)