TradeExamPro

Elevator Contractor Practice Test

Practice questions on elevator and escalator systems, hoistways, controls, safety devices, inspection and testing, and licensing, based on the ASME elevator safety code and public regulations.

188 questions · 6 topics · start free, no sign-up

Start practising

Mixed practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

A contractor is told the elevator code is 'ASME A17.1' but the state may be on an older edition. Who decides which edition applies to a job in that state?

  1. The maker of the equipment installed
  2. The authority having jurisdiction that adopted the code
  3. The insurer of the building owner
  4. ASME, which enforces its codes directly
Show the answer

B. The authority having jurisdiction that adopted the code

ASME writes the code, but it has no enforcement power. The state or local authority adopts a specific edition by law or rule. Manufacturers and insurers can add requirements but cannot change the legal edition.

Reference: ASME A17.1-2025/CSA B44:25, foreword; adopting jurisdiction's elevator rules

A traction elevator is stopped at a floor with passengers inside and a call has come in. What is the mechanic's first priority on arrival?

  1. Make sure the passengers are safe and communicate with them
  2. Open the controller and start measuring voltages
  3. Reset the car and ignore the cause
  4. Remove the governor rope to check it
Show the answer

A. Make sure the passengers are safe and communicate with them

Passenger safety and calm communication come first. Troubleshooting starts only after people are safe, and resetting without finding the cause lets the fault repeat. Removing the governor rope is never a first step.

Reference: ASME A17.1-2025/CSA B44:25, Part 8 (emergency and callback response)

On an escalator, what does the skirt obstruction device do?

  1. Keeps the skirt panel painted a contrasting color
  2. Slows the handrail when the skirt is hot
  3. Stops the escalator when something is caught between a step and the skirt panel
  4. Stops the escalator only when the comb plate is removed for cleaning
Show the answer

C. Stops the escalator when something is caught between a step and the skirt panel

The skirt panel runs alongside the steps and a trapped shoe or object can be dragged into the gap. The device senses this and stops the unit. It is not a comb or handrail device.

Reference: ASME A17.1-2025/CSA B44:25, Part 6 (escalators and moving walks); device purpose is the same under the 2022 edition

A firefighter is using Phase II in-car operation and wants the car to stay at a floor with the doors open while he works. Which key switch position does this?

  1. OFF
  2. HOLD
  3. ON
  4. BYPASS
Show the answer

B. HOLD

The Phase II switch has OFF, ON and HOLD. HOLD keeps the car at the landing with the doors open. ON gives normal in-car control, and BYPASS is a Phase I position.

Reference: ASME A17.1-2025/CSA B44:25, Section 2.27.3

Under ASME A17.1-2025 (same rule as the 2022 edition), the governor must trip at no less than what percent of the car's rated speed?

  1. 100 percent
  2. 105 percent
  3. 110 percent
  4. 115 percent
Show the answer

D. 115 percent

The minimum governor tripping speed is 115 percent of rated speed, so normal running never trips it. A trip point at or near rated speed would cause nuisance trips.

Reference: ASME A17.1-2025/CSA B44:25 (rule identical in ASME A17.1-2022/CSA B44:22), Section 2.18

Exams this helps with

ExamWho runs itWhere
Elevator contractorState boardsUnited States (varies by state)