Practice questions on elevator and escalator systems, hoistways, controls, safety devices, inspection and testing, and licensing, based on the ASME elevator safety code and public regulations.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor and the seller of record, adds tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@tradeexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the mock exam to use it.
A contractor is told the elevator code is 'ASME A17.1' but the state may be on an older edition. Who decides which edition applies to a job in that state?
The maker of the equipment installed
The authority having jurisdiction that adopted the code
The insurer of the building owner
ASME, which enforces its codes directly
Show the answer
B. The authority having jurisdiction that adopted the code
ASME writes the code, but it has no enforcement power. The state or local authority adopts a specific edition by law or rule. Manufacturers and insurers can add requirements but cannot change the legal edition.
Reference: ASME A17.1-2025/CSA B44:25, foreword; adopting jurisdiction's elevator rules
A traction elevator is stopped at a floor with passengers inside and a call has come in. What is the mechanic's first priority on arrival?
Make sure the passengers are safe and communicate with them
Open the controller and start measuring voltages
Reset the car and ignore the cause
Remove the governor rope to check it
Show the answer
A. Make sure the passengers are safe and communicate with them
Passenger safety and calm communication come first. Troubleshooting starts only after people are safe, and resetting without finding the cause lets the fault repeat. Removing the governor rope is never a first step.
Reference: ASME A17.1-2025/CSA B44:25, Part 8 (emergency and callback response)
On an escalator, what does the skirt obstruction device do?
Keeps the skirt panel painted a contrasting color
Slows the handrail when the skirt is hot
Stops the escalator when something is caught between a step and the skirt panel
Stops the escalator only when the comb plate is removed for cleaning
Show the answer
C. Stops the escalator when something is caught between a step and the skirt panel
The skirt panel runs alongside the steps and a trapped shoe or object can be dragged into the gap. The device senses this and stops the unit. It is not a comb or handrail device.
Reference: ASME A17.1-2025/CSA B44:25, Part 6 (escalators and moving walks); device purpose is the same under the 2022 edition
A firefighter is using Phase II in-car operation and wants the car to stay at a floor with the doors open while he works. Which key switch position does this?
OFF
HOLD
ON
BYPASS
Show the answer
B. HOLD
The Phase II switch has OFF, ON and HOLD. HOLD keeps the car at the landing with the doors open. ON gives normal in-car control, and BYPASS is a Phase I position.
Under ASME A17.1-2025 (same rule as the 2022 edition), the governor must trip at no less than what percent of the car's rated speed?
100 percent
105 percent
110 percent
115 percent
Show the answer
D. 115 percent
The minimum governor tripping speed is 115 percent of rated speed, so normal running never trips it. A trip point at or near rated speed would cause nuisance trips.