Hoistways pits machine rooms practice questions

32 questions from the Elevator contractor practice test.

Start practising

Hoistways pits machine rooms practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Sample questions

A firefighter is using Phase II in-car operation and wants the car to stay at a floor with the doors open while he works. Which key switch position does this?

  1. OFF
  2. HOLD
  3. ON
  4. BYPASS
Show the answer

B. HOLD

The Phase II switch has OFF, ON and HOLD. HOLD keeps the car at the landing with the doors open. ON gives normal in-car control, and BYPASS is a Phase I position.

Reference: ASME A17.1-2025/CSA B44:25, Section 2.27.3

Why must a permanent pit ladder reach above the access door sill?

  1. So the car cannot run over it
  2. So it can be used as a ground
  3. For handhold when stepping on/off
  4. So the pit can be ventilated
Show the answer

C. For handhold when stepping on/off

Extending the ladder above the sill gives a hand grip at the moment of transition, when falls happen. Ladder length has nothing to do with ventilation or grounding.

Reference: ASME A17.1-2025/CSA B44:25, Section 2.2 (pit access)

NEC 2023 requires GFCI protection for certain receptacles in elevator pits and machine rooms. Which receptacles?

  1. Only 480-volt receptacles
  2. Only receptacles on the car
  3. Only receptacles in the machine room ceiling
  4. 125-volt, 15- and 20-ampere receptacles
Show the answer

D. 125-volt, 15- and 20-ampere receptacles

Pits are damp and workers stand on conductive surfaces, so the common 125-volt, 15 and 20 ampere outlets need ground-fault protection. High voltage motor feeders are not what this rule covers.

Reference: NEC 2023, 620.85