With 2:1 roping, the car moves at 400 feet per minute. How fast are the hoist ropes moving at the drive sheave?
800 feet per minute
200 feet per minute
400 feet per minute
1,600 feet per minute
Show the answer
A. 800 feet per minute
With 2:1 roping the ropes travel twice as far as the car, so rope speed is double the car speed. 200 fpm is the mistake of dividing instead of multiplying.
Reference: Elevator mechanical arithmetic (speed, force and pressure relationships)
A machine-room-less elevator differs from a conventional traction elevator mainly because the
machine is located in the hoistway or its headroom
car is driven by a hydraulic jack
ropes are replaced by chains only
counterweight is not required
Show the answer
A. machine is located in the hoistway or its headroom
A machine-room-less unit places the compact drive in the hoistway, usually at the top or on a rail, instead of a separate room. It is still a roped traction unit with a counterweight.
Reference: ASME A17.1-2025/CSA B44:25, Part 2 (electric elevators); roping and machine principles
A hydraulic elevator car settles slowly downward at a floor with the pump off. What is the most likely cause?
Oil tank is overfilled
Oil leaking past a valve seat
Ropes are too tight
Car is lightly loaded
Show the answer
B. Oil leaking past a valve seat
With the pump off, the trapped oil must hold the car; a creep down means oil is passing a leaking check or down valve seat, or the jack packing. Overfilled tanks do not move the car.
Reference: ASME A17.1-2025/CSA B44:25, Part 3 (hydraulic elevators); hydraulic power unit principles