Practice questions on sprinkler systems, water supply and testing, fire alarm, security and access systems, and life safety basics. Each code question names the edition of the standard.

205 questions · 6 topics · start free, no sign-up

Start practising

Mixed practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

A Class A pathway between a control unit and its devices suffers a single open on one conductor. What happens?

  1. Signals still arrive over the return path and trouble is shown
  2. Every device past the break is cut off and no trouble is shown
  3. Devices past the break go into alarm until the wire is repaired
  4. The control unit shuts down until the open is found and fixed
Show the answer

A. Signals still arrive over the return path and trouble is shown

A Class A pathway has a return path, so signals can still reach the control unit from both ends of the break while a trouble signal reports the fault. A Class B pathway is the one where devices past an open are cut off, though trouble is still shown.

Reference: NFPA 72 (2025), Chapter 12, circuits and pathways (Class A and Class B)

A magnesium shaving fire starts in a machine shop. Which agent is the right type for it?

  1. Class D dry powder agent
  2. ABC dry chemical
  3. Water from a fire hose line
  4. Carbon dioxide gas
Show the answer

A. Class D dry powder agent

Burning magnesium needs a dry powder agent listed for combustible metals, which smothers the fire. Water can react violently with burning metals, and ABC dry chemical and CO2 are not made for them.

Reference: NFPA 10 (2022 edition), Chapter 5

A fire alarm cable must be run through an air-handling plenum with no metal raceway. Under the NEC (NFPA 70) 2023, which listed cable type fits?

  1. FPL
  2. FPLR
  3. FPLP
  4. NPLF
Show the answer

C. FPLP

FPLP is the plenum-rated power-limited fire alarm cable. FPL is for general use and FPLR for risers; neither is listed for plenum use without a raceway.

Reference: NEC (NFPA 70) 2023, 760.154

A shop has large front windows and the owner wants an alarm when someone breaks the glass without having to open the door. Which device is designed for this?

  1. A magnetic door contact
  2. A smoke detector
  3. A request-to-exit sensor
  4. A glass-break detector
Show the answer

D. A glass-break detector

A glass-break detector listens for the sound and shock signature of breaking glass and covers a whole room of windows. A door contact only sees the door move, so a broken window would go unnoticed.

Reference: Intrusion alarm installation practice: perimeter protection devices

Under NFPA 13 2025, which occupancy is normally classified as Light Hazard?

  1. An aircraft hangar
  2. A vehicle parking garage
  3. A general office space
  4. A plastics processing plant
Show the answer

C. A general office space

Offices have low quantity and low combustibility of contents, which fits Light Hazard. Parking garages are Ordinary Group 1, hangars are Extra Hazard Group 1, and plastics processing is Extra Hazard Group 2.

Reference: NFPA 13 2025, occupancy hazard classification chapter and Annex A (Light Hazard examples)

Exams this helps with

ExamWho runs itWhere
Alarm / security systems contractorState boardsUnited States (varies by state)
Fire alarm systems Levels I to IVNICETUnited States
Fire alarm technician / RME state licenseState fire marshalsUnited States (varies by state)
Fire protection contractorState boards, state fire marshalsUnited States (varies by state)