Asbestos, Mold and Radon Professional Practice Test
Practice questions on asbestos rules and abatement, mold assessment and remediation principles, and radon measurement and mitigation, based on public federal rules and EPA guidance.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor and the seller of record, adds tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@tradeexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the mock exam to use it.
A single homogeneous area of friable sprayed-on ceiling surfacing covers 3,500 square feet. At minimum, how many bulk samples does the AHERA inspection rule call for?
3
7
9
5
Show the answer
D. 5
For surfacing material, 1,000 sq ft or less needs 3 samples, more than 1,000 up to 5,000 sq ft needs 5, and more than 5,000 sq ft needs 7. At 3,500 sq ft the middle tier applies, so 3 is too few.
Reference: 40 CFR 763.86
A crew will remove asbestos-containing vinyl floor tile. Which OSHA class of work is this?
Class I
Class II
Class III
Class IV
Show the answer
B. Class II
Removing ACM that is not thermal insulation or surfacing material, such as floor tile, sheeting, roofing or siding, is Class II. Class I is limited to thermal system insulation and surfacing material.
Reference: OSHA 29 CFR 1926.1101(b), definition of Class II work
Dust in an area is measured at 30 times its exposure limit. Which respirator is the lowest-protection choice that still has an adequate APF?
B. Full facepiece air-purifying respirator (APF 50)
The APF must be at least the hazard ratio, here 30. The full facepiece respirator at 50 qualifies. The hood at 25 looks close but falls short, and the half-mask and quarter-mask are far below 30.
A homeowner finds visible mold on a bathroom wall. What does EPA guidance say about sampling here?
Usually unneeded; clean visible mold
It is always required before any cleaning starts
It is required to prove the mold type to the city
It must be done by the homeowner with a home kit
Show the answer
A. Usually unneeded; clean visible mold
When mold is visible, sampling is usually not needed because the response is the same: fix the moisture and remove the growth. Sampling answers special questions; it is not a routine first step.
Reference: EPA, Mold Remediation in Schools and Commercial Buildings (EPA 402-K-01-001), Chapter 3 (sampling)
For how long before a short-term radon test starts must closed-building conditions be kept?
About 1 hour
At least 12 hours
About 3 days
Only after the device is placed
Show the answer
B. At least 12 hours
Closed-building conditions mean keeping windows and outside doors shut except for normal entry and exit, starting at least 12 hours before the test and continuing through it. Starting late lets outdoor air dilute the indoor level.
Reference: EPA, Home Buyer's and Seller's Guide to Radon