TradeExamPro

Radon mitigation practice questions

36 questions from the Asbestos, mold and radon practice test.

Start practising

Radon mitigation practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Sample questions

Why should a radon fan not be placed in a basement or crawlspace?

  1. The fan would overheat from the warm, still basement air
  2. Positive pressure after fan could leak indoors
  3. The fan blades would be slowed by the damp basement air
  4. The suction pipe would be too short to reach the soil below
Show the answer

B. Positive pressure after fan could leak indoors

Downstream of the fan the pipe carries soil gas above room pressure. Any leak there pushes radon into the living area, so the fan goes outdoors, in an attic or in another unoccupied space. Heat and humidity are not the reason.

Reference: ANSI/AARST SGM-SF-2023 (soil gas mitigation in existing homes)

Why are cracks and openings in a slab sealed when a sub-slab system is installed?

  1. To make the slab waterproof against rain
  2. To make the fan run backward when it is off
  3. To raise the pressure of the soil gas under the slab
  4. So the fan pulls less room air and more suction reaches the soil
Show the answer

D. So the fan pulls less room air and more suction reaches the soil

Sealing reduces leakage between the room and the sub-slab area. The fan then spends its capacity on soil gas rather than conditioned room air, and fewer entry paths remain. Sealing alone usually does not give reliable reduction.

Reference: ANSI/AARST SGM-SF-2023 (soil gas mitigation in existing homes)

A home tests 12.4 pCi/L before mitigation and 2.9 pCi/L afterward. By what percent was radon reduced?

Answer in %.

Show the answer

76.6 %

Reduction = (12.4 - 2.9) / 12.4 = 9.5 / 12.4 = 0.766, or 76.6%. A common slip is dividing by the after reading.

Reference: EPA Consumer's Guide to Radon Reduction