Dust in an area is measured at 30 times its exposure limit. Which respirator is the lowest-protection choice that still has an adequate APF?

  1. Half-mask air-purifying respirator (APF 10)
  2. Full facepiece air-purifying respirator (APF 50)
  3. Loose-fitting hood powered air-purifying respirator (APF 25)
  4. Quarter-mask air-purifying respirator (APF 5)
Show the answer

B. Full facepiece air-purifying respirator (APF 50)

The APF must be at least the hazard ratio, here 30. The full facepiece respirator at 50 qualifies. The hood at 25 looks close but falls short, and the half-mask and quarter-mask are far below 30.

Reference: OSHA 29 CFR 1910.134(d)(3)(i)(A), Table 1

A worker with a full beard asks to use a tight-fitting half-mask respirator. What does the standard say?

  1. It is allowed if the worker passes a seal check once
  2. It is allowed if the beard is trimmed under the chin only
  3. It is not allowed if hair comes between the sealing surface and the face
  4. It is allowed if the filters are changed more often
Show the answer

C. It is not allowed if hair comes between the sealing surface and the face

Facial hair that lies where the facepiece seals to the skin prevents tight-fitting respirators from being used. A seal check or more frequent filter changes cannot make up for a leaking seal. The worker would need a loose-fitting hood or a clean-shaven seal area.

Reference: OSHA 29 CFR 1910.134(g)(1)(i)

How often must an employee who wears a tight-fitting respirator be fit tested again with the same make, model and size?

  1. Every 5 years
  2. Only when the respirator wears out
  3. Only after a medical evaluation
  4. At least once every 12 months
Show the answer

D. At least once every 12 months

Fit testing is required before first use and then at least annually. It is also repeated when a different facepiece size, style, model or make is used.

Reference: OSHA 29 CFR 1910.134(f)(2)