10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
A crew will remove asbestos-containing vinyl floor tile. Which OSHA class of work is this?
Class I
Class II
Class III
Class IV
Show the answer
B. Class II
Removing ACM that is not thermal insulation or surfacing material, such as floor tile, sheeting, roofing or siding, is Class II. Class I is limited to thermal system insulation and surfacing material.
Reference: OSHA 29 CFR 1926.1101(b), definition of Class II work
An electrician must drill through asbestos pipe insulation to hang a bracket. The insulation will be disturbed but not removed. Which class of work is this?
Class I work
Class II
Class IV
Class III
Show the answer
D. Class III
Repair and maintenance work likely to disturb ACM is Class III. It is not Class I because the insulation is not being removed, and not Class IV because the material is actually disturbed.
Reference: OSHA 29 CFR 1926.1101(b), definition of Class III work
On an asbestos job, which description fits a regulated area?
Marked area for Class I-III or >PEL
Any room in the building that has ACM somewhere inside it
The truck and dumpster area outside the building only
Only the decontamination unit and nothing else around it
Show the answer
A. Marked area for Class I-III or >PEL
A regulated area is marked off where Class I, II or III work happens, and also includes any area where airborne asbestos is, or may reasonably be expected to be, over the PEL. Having ACM in a room does not by itself make it regulated.