TradeExamPro

Asbestos inspection abatement practice questions

36 questions from the Asbestos, mold and radon practice test.

Start practising

Asbestos inspection abatement practice test

10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.

Sample questions

A single homogeneous area of friable sprayed-on ceiling surfacing covers 3,500 square feet. At minimum, how many bulk samples does the AHERA inspection rule call for?

  1. 3
  2. 7
  3. 9
  4. 5
Show the answer

D. 5

For surfacing material, 1,000 sq ft or less needs 3 samples, more than 1,000 up to 5,000 sq ft needs 5, and more than 5,000 sq ft needs 7. At 3,500 sq ft the middle tier applies, so 3 is too few.

Reference: 40 CFR 763.86

An inspector samples a homogeneous area of pipe insulation that is not assumed to be asbestos. What is the general minimum number of randomly placed bulk samples?

  1. 3
  2. 1
  3. 5
  4. 7
Show the answer

A. 3

Thermal system insulation needs at least 3 randomly distributed samples per homogeneous area. One sample applies only to small patched sections, and 5 and 7 are surfacing tiers.

Reference: 40 CFR 763.86

Which of these is a Category I non-friable asbestos-containing material under NESHAP?

  1. Cement siding panels
  2. Sprayed-on fireproofing
  3. Resilient floor covering
  4. Plaster that has been crushed
Show the answer

C. Resilient floor covering

NESHAP Category I non-friable material is limited to packings, gaskets, resilient floor covering and asphalt roofing products. Cement siding is Category II, and sprayed fireproofing is friable.

Reference: 40 CFR 61.141