What is the main job of the riving knife on a table saw?

  1. Hold the board down flat on the table
  2. Stop the cut closing on the blade and kicking back
  3. Catch the dust from the cut
  4. Set the depth of the blade
Show the answer

B. Stop the cut closing on the blade and kicking back

The riving knife rides just behind the blade in the kerf and stops the cut edges from closing on the blade, a common cause of kickback. It does not hold the board down or collect dust.

Reference: Manufacturer operating instructions for table saws; CCOHS: Table saw safety; Red Seal Occupational Standard for Carpenter (2022): occupational skills tasks

Which nail gun trigger mode is most likely to fire a nail by accident when the nose bumps a person or an object while the trigger is held?

  1. Sequential trip
  2. Trigger locked out
  3. Contact (bump) trip
  4. Air hose disconnected
Show the answer

C. Contact (bump) trip

In contact (bump) mode, the gun fires each time the nose touches the work while the trigger is held, so an accidental bump can drive a nail. Sequential mode needs the nose pressed first and then the trigger pulled, which is safer.

Reference: Manufacturer operating instructions for pneumatic nailers; CCOHS: Nail guns; Red Seal Occupational Standard for Carpenter (2022): occupational skills tasks

On a job site, why should portable power tools be plugged into a ground fault circuit interrupter (GFCI)?

  1. It keeps the tool at a steady speed
  2. It lets a long cord carry more current
  3. It stops the tool overheating under load
  4. It trips fast if current leaks to ground through a person
Show the answer

D. It trips fast if current leaks to ground through a person

A GFCI senses current that is leaking out of the normal path, for example through a person, and trips in a fraction of a second. It does not regulate speed, increase cord capacity or protect against overload.

Reference: Canadian Electrical Code, Part I, 2024 edition (CSA C22.1:24), Section 76 temporary wiring on construction sites; provincial OHS regulations; Red Seal Occupational Standard for Carpenter (2022): occupational skills tasks