10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
In a two-storey house, an interior wall runs at right angles to the floor joists above and sits near the middle of their span. What is the most likely conclusion?
It is probably bearing and should not be removed without engineered advice
It is a partition and can be removed freely
It carries only the ceiling drywall
It can be judged non-bearing because it is thin
Show the answer
A. It is probably bearing and should not be removed without engineered advice
A wall perpendicular to joists near mid-span usually holds up those joists, so it is likely bearing. Wall thickness says nothing about load, which is why the thin-wall reasoning is wrong.
Reference: Red Seal Occupational Standard, Carpenter (2022): assess existing structures; framing load-path principles
While opening an attic you find loose, pebble-like grey-brown insulation. How should it be treated?
As ordinary wood-fibre insulation to be vacuumed up
As harmless because it is dry
As possibly containing asbestos until tested
As safe if you wear a paper dust mask
Show the answer
C. As possibly containing asbestos until tested
Loose-fill vermiculite insulation has been associated with asbestos contamination, so it is treated as suspect until a lab says otherwise. Ordinary vacuuming and a paper mask do not control asbestos fibres.
Reference: Health Canada guidance on vermiculite insulation; provincial asbestos regulations
A sagging floor joist is being strengthened by fastening a new joist alongside it. Which way should the crown of the new joist face?
Down, to pull the old joist up
Up, the same way as the existing joist
Sideways, to resist twisting
It does not matter if glued and nailed
Show the answer
B. Up, the same way as the existing joist
Joists are installed crown up so that load flattens the natural bow and the floor ends up level. A crown-down joist would sag further under load.
Reference: Red Seal Occupational Standard, Carpenter (2022): floor framing and repair; framing practice for joist crown