Drywall, Painting, Flooring, Insulation and Glazing Contractor Practice Test
Practice questions on drywall and framing, painting and coatings, flooring and tile, insulation and glazing work, with shared questions on safety, estimating and business. Built from public safety rules and widely used industry practice.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor and the seller of record, adds tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@tradeexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the mock exam to use it.
For many listed one-hour wall assemblies, what single layer of gypsum board is typically applied to each side of the studs?
1/2 inch regular
3/8 inch regular
1/4 inch flexible
5/8 inch Type X
Show the answer
D. 5/8 inch Type X
Common one-hour listings use one layer of 5/8 inch Type X on each side. Regular half-inch board does not have the fire-resistant core and will not achieve the rating.
Reference: GA-600 Fire Resistance Design Manual (listed assembly governs)
Before bidding work in a new city, a painting contractor wants to know if a licence is needed. What is the correct first step?
Assume the home state licence is valid there
Check state and local licensing
Ask the owner, who must know the rules
Start work and apply once the job is awarded
Show the answer
B. Check state and local licensing
Licensing is set by state and local authorities and varies widely, so the contractor should check with them before bidding. An owner is not the authority, and working first can bring penalties and may block collection of payment.
Reference: State and local contractor licensing board rules (vary by jurisdiction)
Which backer is the better choice for a tile tub surround in a wet area?
Standard paper-faced gypsum drywall
Untreated hardboard
Cementitious backer board
Foam board with no facing
Show the answer
C. Cementitious backer board
Cement backer board does not soften when it gets wet. Standard paper-faced drywall loses strength with moisture and is not a tile base in wet areas.
Reference: ANSI A118.9; TCNA Handbook for Ceramic, Glass, and Stone Tile Installation (current edition)
A heat-strengthened lite is best described as which of the following?
The same as fully tempered glass but cheaper
Stronger than annealed, not safety
Weaker than annealed glass but safer when broken
Laminated glass without the interlayer
Show the answer
B. Stronger than annealed, not safety
Heat-strengthened glass has a lower surface stress than fully tempered glass. It resists thermal stress better than annealed, but it breaks into larger pieces and does not qualify as safety glazing. Calling it tempered is the common mix-up.
Reference: ASTM C1048, heat-treated flat glass
Why is sealing air leaks at the ceiling often more important for moisture control than choosing a vapor retarder?
Air leaks only affect comfort and never carry moisture
Moving air carries far more water vapor into an assembly than diffusion through solid material
Diffusion moves much more moisture than any air leak can
Sealed ceilings do not need insulation at all
Show the answer
B. Moving air carries far more water vapor into an assembly than diffusion through solid material
Air passing through gaps around wires, pipes and top plates carries moisture with it in quantities that diffusion through a solid layer cannot match. That is why air sealing comes first. Saying leaks only affect comfort ignores the moisture they deposit on cold surfaces.
Reference: ASHRAE Handbook of Fundamentals, heat transfer and moisture control chapters; Building America Solution Center air sealing guidance