10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
Why is sealing air leaks at the ceiling often more important for moisture control than choosing a vapor retarder?
Air leaks only affect comfort and never carry moisture
Moving air carries far more water vapor into an assembly than diffusion through solid material
Diffusion moves much more moisture than any air leak can
Sealed ceilings do not need insulation at all
Show the answer
B. Moving air carries far more water vapor into an assembly than diffusion through solid material
Air passing through gaps around wires, pipes and top plates carries moisture with it in quantities that diffusion through a solid layer cannot match. That is why air sealing comes first. Saying leaks only affect comfort ignores the moisture they deposit on cold surfaces.
Reference: ASHRAE Handbook of Fundamentals, heat transfer and moisture control chapters; Building America Solution Center air sealing guidance
In winter, warm air in a house tends to rise and leak out through gaps in the ceiling while cold air enters low in the house. What is this effect called?
Thermal bridging
Wind washing
Stack effect
Vapor drive
Show the answer
C. Stack effect
Stack effect is the pressure difference created by warm air rising, which pulls in cold air at the bottom and pushes warm air out at the top. Thermal bridging is heat moving through framing, wind washing is wind blowing through insulation, and vapor drive is diffusion, so none of them describe this.
Reference: ASHRAE Handbook of Fundamentals, heat transfer and moisture control chapters
You are blowing insulation in an attic that has recessed ceiling lights. What must you check before covering a fixture?
Whether the bulb is LED or incandescent
Whether the attic has a ridge vent
Whether the ceiling is painted
Whether the fixture is marked as rated for contact with insulation
Show the answer
D. Whether the fixture is marked as rated for contact with insulation
A fixture that is not marked for insulation contact can overheat if buried, so the marking decides whether insulation may touch it. Otherwise keep the insulation back from the housing or install a proper cover as the manufacturer allows. The bulb type and the vent do not answer that question.
Reference: UL 1598 luminaire marking for insulation contact; fixture manufacturer instructions