10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
For many listed one-hour wall assemblies, what single layer of gypsum board is typically applied to each side of the studs?
1/2 inch regular
3/8 inch regular
1/4 inch flexible
5/8 inch Type X
Show the answer
D. 5/8 inch Type X
Common one-hour listings use one layer of 5/8 inch Type X on each side. Regular half-inch board does not have the fire-resistant core and will not achieve the rating.
Reference: GA-600 Fire Resistance Design Manual (listed assembly governs)
How should a drywall screw sit when it is driven correctly?
At a slant so the head grips the paper edge
Deep enough to cut through the paper
Dimpled without breaking face paper
Left proud so compound can cover it
Show the answer
C. Dimpled without breaking face paper
A slight dimple lets the head be filled with compound while the paper still holds the board. A screw that breaks the paper loses holding power; a proud head shows through the finish.
Reference: GA-216 Application and Finishing of Gypsum Panel Products
What is the best backer for ceramic tile on a tub surround?
Standard 1/2 inch gypsum board
Fire-rated Type X board
Cement backer board
Plywood without a barrier
Show the answer
C. Cement backer board
Cement board stays stable when wet. Standard gypsum board softens when moisture reaches it and fails behind tile; Type X is a fire product, not a wet-area product.
Reference: ANSI A118.9 Cementitious Backer Units; GA-216 Application and Finishing of Gypsum Panel Products