10 questions, graded as you go, with the reason for every answer. Start free, no sign-up.
Sample questions
A debris chute is steeper than 45 degrees from the horizontal. What does the standard require of it?
It may stay open on one side
It must be fully enclosed
It needs a handrail only
It must be painted yellow
Show the answer
B. It must be fully enclosed
Chutes steeper than 45 degrees must be fully enclosed so falling material cannot escape. A handrail does not contain debris.
Reference: 29 CFR 1926.852(b) (eCFR, current as of November 2026)
What is the maximum height of a loading opening in a debris chute?
24 inches
60 inches
48 inches
72 inches
Show the answer
C. 48 inches
Loading openings may not be more than 48 inches high, and on stories below the top they stay closed when not in use. A taller opening lets debris and people slip into the chute.
Reference: 29 CFR 1926.852(b) (eCFR, current as of November 2026)
Debris is being dropped through a floor hole. How far back from the projected edge of the opening above must the barricade below be set?
Not less than 1 foot
Not less than 3 feet
Not less than 10 feet
Not less than 6 feet
Show the answer
D. Not less than 6 feet
The barricade below a debris drop must be at least 42 inches high and at least 6 feet back from the projected edge of the opening. Closer barriers leave people within reach of bouncing debris.
Reference: 29 CFR 1926.850(h) (eCFR, current as of November 2026)